1、BRITISH STANDARD BS 6037-2:2004 Code of practice for the planning, design, installation and use of permanently installed access equipment Part 2: Travelling ladders and gantries ICS 53.020.99 ? BS 6037-2:2004 This British Standard was published under the authority of the Standards Policy and Strateg
2、y Committee on 16 September 2004 BSI 16 September 2004 The following BSI references relate to the work on this British Standard: Committee reference B/514/39 Draft for comment 04/30092680 DC ISBN 0 580 44352 3 Committees responsible for this British Standard The preparation of this British Standard
3、was entrusted by Technical Committee, B/514, Access and support equipment to B/514/39, Suspended access equipment, upon which the following bodies were represented: Association of Technical Lighting and Access Specialists Construction Industry Training Board Health and Safety Executive National Acce
4、ss and Scaffolding Confederation Safety Assessment Federation Limited Society of Operations Engineers Suspended Access Equipment Manufacturers Association Amendments issued since publication Amd. No.DateComments BS 6037-2:2004 BSI 16 September 2004 i Contents Page Committees responsible Inside front
5、 cover Forewordii Introduction1 1Scope1 2Normative references1 3Terms and definitions2 4Identifying hazards and taking preventative action2 5Planning and exchange of information4 6Health and Safety5 7Attachment of the TLG to the building6 8Track system7 9Design recommendations for TLGs8 10Ancillary
6、features of TLGs12 11Protection against lightning13 12Electrical systems13 13Hydraulic and pneumatic systems13 14Control systems14 15Safety devices14 16Marking14 17Commissioning, verification and handover15 18Responsibilities of the duty holder15 19Instructions for use16 20Provision of notices17 21T
7、raining and instruction17 22Inspections, maintenance, thorough examinations and testing17 23Record keeping20 24Changes to the TLG20 Bibliography21 Table 1 Hazards encountered when installing, maintaining and using TLGs, and recommended actions3 Table 2 Safe use of TLGs6 BS 6037-2:2004 ii BSI 16 Sept
8、ember 2004 Foreword Technical Committee B/514/39 has prepared this part of BS 6037. This part of BS 6037 covers the planning, design, installation and use of travelling ladders and gantries. As a code of practice this British Standard takes the form of guidance and recommendations. It should not be
9、quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading. It has been assumed in the preparation of this standard that the execution of its provisions will be entrusted to appropriately qualified and experienced people for whose
10、use it has been produced. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises
11、 a front cover, an inside front cover, pages i and ii, pages 1 to 21 and a back cover The BSI copyright notice displayed in this document indicates when the document was last issued. w w w . b z f x w . c o m BS 6037-2:2004 BSI 16 September 2004 1 Introduction It is increasingly common for modern co
12、mmercial office buildings to incorporate an atrium and/or a glazed corridor, glazed entrance or roof that requires special provision for continuing maintenance access. Modern shopping malls also often incorporate extensive, high-level glazed roofs which are difficult to access using mobile equipment
13、. The Construction (Design and Management) Regulations 1994 (CDM Regulations) 1 require that all faades and other items that require periodic access are designed and positioned so that they can be accessed safely. To keep these often large and inaccessible areas of glass clean and also to provide sa
14、fe access for the routine maintenance of items such as lights and smoke detectors, these buildings should be provided with some form of permanently installed appliance, which could be in the form of a travelling ladder or gantry, sometimes used in conjunction with a suspended platform. It is essenti
15、al that the requirements for permanently installed access equipment be considered at an early stage in the building design process. The dimensions and capability of any travelling ladder or gantry need to be appropriate for the nature of the task(s) to be performed. The installation can be manually
16、or power operated or a combination of both. It should be noted that working at height can expose workers and other persons in the vicinity to particularly severe risks to their health and safety, in particular the risk of falling from height, falling objects and other serious occupational accidents.
17、 1 Scope This part of BS 6037 gives recommendations for the planning, design, installation, use, examination, maintenance and testing of permanently installed travelling ladders and gantries (TLGs) including equipment installed on a building to facilitate routine maintenance of the building fabric a
18、nd its services. It is intended for those involved in specifying, designing, managing the use of, maintaining and examining such equipment. This standard does not cover TLG systems designed for heavy duty and industrial applications such as underbridge gantries or gantries for industrial processes.
19、Where TLGs are intended to be used in conjunction with suspended access equipment (SAE), this code of practice is supplemented by BS EN 1808:1999 and BS 6037-1:2003. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references
20、, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. BS 449-2, Specification for the use of structural steel in building Part 2: Metric units. BS 4211, Specification for ladders for access to chimneys, other high
21、structures, silos and bins. BS 5268-2, Structural use of timber Part 2: Code of practice for permissible stress design, materials and workmanship. BS 5395-3:1985, Stairs, ladders and walkways Part 3: Code of practice for the design of industrial type stairs, permanent ladders and walkways. BS 5950 (
22、all parts), Structural use of steelwork in building. BS 6037-1:2003, Code of practice for the planning, design, installation and use of permanently installed access equipment Part 1: Suspended access equipment. BS 7671, Requirements for electrical installations IEE Wiring Regulations. BS 7883, Code
23、of practice for application and use of anchor devices conforming to BS EN 795. BS 8110 (all parts), Structural use of concrete. BS 8118 (all parts), Structural use of aluminium. BS EN 795, Protection against falls from height Anchor devices Requirements and testing. w w w . b z f x w . c o m BS 6037
24、-2:2004 2 BSI 16 September 2004 BS EN 1808:1999, Safety requirements on suspended access equipment Design calculations, stability criteria, construction Tests. BS EN 60204-1, Safety of machinery Electrical equipment of machines Part 1: General requirements. BS EN 60947-3, Specification for low-volta