1、Procedure of Install PAD Vanguard 200Edited by : Zhou jian qiu1997/08/071. Data base for creating X.25 link for PAD EWSD V9 or V6.2 in CP113 or CP113C/*/* CREATE I/O PROCESSORS FOR LAU */*/CMDFILE;SETCFOPT:ACKCFS=ERROR,DANCMD=EXEC,ACKREQ=POS;/CRIOP:IOC=1,BIOC=11,IOP=IOPLAU-0,IOPR=IOPLAU-1,BIOCR=11,L
2、OADTP=100,LDPRTY=LOW;CONFIOP:IOP=IOPLAU-0,OST=MBL;CONFLAU:LAU=0,OST=MBL;/* X25 LINK FOR PVC DIALOG FUNCTION VIA PAD/CRX25LINK:X25LINK=1,LAU=0,CHAN=1,NET=X25LC,PRTCL=BX25,L1BAUD=B9600,L1DTT=DCE,#L1IF=V24,L1MCA=1,L2DTT=DCE,L2LAM=INITIA,L2N2=10,L2N1=144,L3DTT=DCE,L3T25=1500;( L1DTT=DTE when via modem,
3、L1VF=X21,L1BAUD=B64000 when PAD using X21 DIM module interface)/CONFX25LINK:X25LINK=1,OST=MBL;/CONFIOP:IOP=IOPLAU-0,OST=ACT;/CONFLAU:LAU=0,OST=ACT;/* LOCAL OSI ADDRESS AND TH25 APPLICATION CROSIADR:ADRNAM=OSILOCH,NSADR=48-0-02,NET=X25LC;CRAPPL:APPLID=TH25,PRONAM=CP02,ADRNAM=OSILOCH; ( CP02 : CP proc
4、essors name)/* REMOTE OSI-ADDRESSES FOR TH25CROSIADR:ADRNAM=OSIRTH01,NSADR=48-0-50,NET=X25LC,LOCADR=OSILOCH;CROSIADR:ADRNAM=OSIRTH02,NSADR=48-0-51,NET=X25LC,LOCADR=OSILOCH;CROSIADR:ADRNAM=OSIRTH03,NSADR=48-0-52,NET=X25LC,LOCADR=OSILOCH;CROSIADR:ADRNAM=OSIRTH04,NSADR=48-0-53,NET=X25LC,LOCADR=OSILOCH;
5、CROSIADR:ADRNAM=OSIRTH05,NSADR=48-0-54,NET=X25LC,LOCADR=OSILOCH;/* REMOTE PROCESSORS FOR TH25CRPRO:PRONAM=TH2501,PROTYP=ANSI; ( VT100)CRPRO:PRONAM=TH2502,PROTYP=ANSI;CRPRO:PRONAM=TH2503,PROTYP=ANSI;CRPRO:PRONAM=TH2504,PROTYP=OMTA; (EWSD-OMT)CRPRO:PRONAM=TH2505,PROTYP=ANSI;/* REMOTE TH25 APPLICATIONS
6、CRAPPL:APPLID=DIAL1,PRONAM=TH2501,ADRNAM=OSIRTH01,AUT=1;CRAPPL:APPLID=DIAL1,PRONAM=TH2502,ADRNAM=OSIRTH02,AUT=1;CRAPPL:APPLID=DIAL1,PRONAM=TH2503,ADRNAM=OSIRTH03,AUT=1;CRAPPL:APPLID=DIAL1,PRONAM=TH2504,ADRNAM=OSIRTH04,AUT=1;CRAPPL:APPLID=DIAL1,PRONAM=TH2505,ADRNAM=OSIRTH05,AUT=1;( APPLID=DIAL2,when
7、processors using for alarm output OMT)/*PVC FOR LINKSCRX25PVC:PVCNAM=THPVC001,ADRNAM=OSIRTH01,X25LINK=1,CHNO=11,PCKSZ=128-128;CRX25PVC:PVCNAM=THPVC002,ADRNAM=OSIRTH02,X25LINK=1,CHNO=12,PCKSZ=128-128;CRX25PVC:PVCNAM=THPVC003,ADRNAM=OSIRTH03,X25LINK=1,CHNO=13,PCKSZ=128-128;CRX25PVC:PVCNAM=THPVC004,ADR
8、NAM=OSIRTH04,X25LINK=1,CHNO=14,PCKSZ=128-128;CRX25PVC:PVCNAM=THPVC005,ADRNAM=OSIRTH05,X25LINK=1,CHNO=15,PCKSZ=128-128;/ CONFX25LINK:X25LINK=1,OST=ACT;RESETCFOPT;ENDFILE;2. Setting PAD Parameter Values1). PAD Vanguard 200PAD V200 FRADSW V.200 OSAKA REV 4.80Port1,2-for 2 X.25 links connection to EWSD
9、IOPSCDP.-DIM V.24 or DIM X.21 also can be used ( module inside vanguard 200 ).-port 1,2 physical address must be set to DCE location when PAD directly connecte to IOPSCDP, when via modem it must be set to DTE. -If only one X.25 link used the other port can be used for connection terminal VT100 or OM